2.6 – Rules as Written: Prescriptive Compliance

Prescriptive Compliance We’ve talked a bit about the Code as our rulebook for construction – how it outlines the different requirements that apply to different parts of our buildings, based on how they’re being used. But when it comes to making sure that the rules are being followed, there are a couple of different ways that the Code allows us to meet with compliance.

The first way is the Prescriptive Path – which really just translates to following the letter of the Code. For any given requirement – be it exit width, fire separation requirements, governing Parts of the Code, or accessible design – we compare a set of drawings, or construction on site to the measurements, ratings, or other requirements that the Code has explicitly provided. In this way, we have a direct path to compliance, because we can simply take something – like a hallway width – and match it, like for like, with whatever the Code has directed.

Diagram comparing obstructions in a corridor
Comparison of obstructions in a corridor, or hallway

It seems pretty straightforward in that way – a lot like when we were previously talking about recipes; if we’re going to bake a cake – we’re given the specific size pan, the specific oven temperature, and even the specific timeline for baking – and if we follow those instructions, we know with almost complete certainty that it will turn out as intended. This generally will be true, regardless of the recipe (or building) that we are working with, because the rules will be there for any situation that we can come up with – for us to review alongside the plans or construction.

In the same way, if we look up the requirements for a corridor (or hallway) width, the number of required toilets in a building, the finishes or materials allowed to be used on a ceiling in a lobby, or even the direction that any given door needs to swing (if it needs to swing in a direction at all) – not only will the Code provide us with this information, but – as long as we follow it directly, we know that we’re guaranteed to meet compliance.

There are some clear benefits to approaching the Code like this – for starters, it gives designers a very clear cut, and straight forward path to compliance. In knowing the exact elements that are required for any given item in their design, less guesswork is required about how compliance needs to be met. This means if someone is developing a project, they can look at a part of their design, and quickly compare what they’re proposing, to what the Code requires, in order to make sure they’re hitting compliance – and hopefully, be able to make changes (easily) if they’re falling short.

Drawing of a barrier-free washroom showing fixture locations

Detailing of a Barrier Free washroom and location of fixtures

Secondly, in following the rules as provided, it develops consistency between projects – which makes it easier for trades, drafts people, and estimators to know what to expect. This can include reusing common details or assemblies (drawings that show how different building parts or materials connect with one another), wall and floor types, even specification sheets. This is a huge advantage, when it comes to pricing, or the predictability of a proposed project for designers and builders alike; if the same assemblies or requirements apply across multiple projects, it can mean faster preparation of plans, permit documents, and material take offs – meaning projects start faster for everyone.

Now that doesn’t mean that there aren’t draw backs as well; sometimes, the Prescriptive requirements can be too restrictive for designers – limiting the materials that can or must be used to achieve compliance. Maybe there is a preference on using wood, like clapboard on the exterior of the building – but the rules that would typically need to be followed say that metal or concrete is required instead. Maybe the structure needs to be the same way, or the finishes on the inside are limited in ways that aren’t ideal.

It can also mean that – in order to meet the letter of the Code, aesthetics or the visual elements of the building, and its layout, no longer work – anything from the amount of glass in a wall, to the types of uses in that space. Maybe wall of windows (known typically as a curtain wall) were part of the plan – but would not be permitted by the rules of the Code. Maybe there is an open lobby that the designer wants to extend up multiple floors, so that you can look down from any level – but the Code would prevent this from going above the first.

Halifax Central Library exterior

Halifax Public Library, an example of a highly complex building

The Code also doesn’t have answers for complex situations (other than prohibiting it, if you’re following the prescriptive rules) – like multiple buildings serving a single group of people (like a spa, or cottage grounds) – to be treated as a single use, or when complex uses try to interact with each other – like a distillery, and a restaurant, for example. Either the situation itself provides a risk that the Code isn’t able to provide direct, and repeatable solution for – or the risks are identified by the Code, and the proposed building (or feature of the building) would add undue risk or complications in spite of the typical requirements. In these cases, designers need to get a bit more inventive; considering how the risks, Objectives, and intents provided by the Code can be met through creative and deliberate alternatives – like modeling, testing, engineered judgments, and new or advanced materials available for the designer or builder.

Login to NSBOA

Access valuable resources, training, and support to advance your career.

Don't have an account? Click here register